TSS EX1 SC TURBIDITY

TSS EX1 sc Turbidity and Suspended Solids Inline Probe, Stainless Steel
The TSS EX1 sc Inline is a digital process probe for the extremely accurate in pipe measurement of turbidity and suspended solids specially designed for use in potentially explosive atmospheres (Class I Div 2).
- Details
- Benefits
- Features
- Applications
- Part & Acc
- Literature
Accuracy | Turbidity up to 1000 NTU: |
< 5% of the measured value ±0.01 NTU | |
Ambient Temperature | 0 – 50 °C |
Application | Hazardous locations |
Automatic Wiper | No |
Cable Length | 10 m (optional extension cables available) |
Calibration | Turbidity (TRB): Factory calibrated |
Solids (TS): To be calibrated by customer on site | |
Zero point: Permanently calibrated in the factory | |
Calibration Method | Turbidity Formazin or StablCal® Standard (at 800 NTU). Requires a calibration kit. |
Suspended Solids Sample specific, based on gravimetric analysis with a correction factor procedure. | |
Controller Compatibility | SC200, SC1000, SC4500. All controllers sold separately |
Diameter | 48.5 mm |
Flow | Max. 3 m/s (the presence of air bubbles affects the measurement) |
Includes | Turbidity & Suspended Solids sensor, user manual |
Installation style | Ball Valve Insertion |
Length | 488 mm |
Maintenance Interval | 1 h/month |
Material | Optics Carrier and Sleeve: stainless steel 1.4460 / stainless steel 1.4404 |
Max Temperature | 50 |
Max. cable length Sensor-to-Controller | 100 |
Measurement Method | Combined multiple beam alternating light method with infrared diode system and beam focusing |
Turbidity (TRB): 2-channel 90º scattered light measurement in accordance with DIN EN ISO 7027, wavelength = 860 nm | |
Solids (TS): 90º and 120º scattered light measurement, wavelength = 860 nm | |
Measuring Principle | Turbidity: 2-channel 90° scattered light measurement in accordance with DIN/EN 27027/ISO7027 |
TSS: Modified absorption measurement | |
Eight-channel multiple-angle measurement, wavelength = 860 nm | |
Model | TSS EX1 sc |
Mounting Configurations | Insertion |
Operating Temperature Range | -10 – 50 °C |
Parameter | Turbidity, Suspended Solids |
Pressure Range | 10 bar or 100 m |
Range | Turbidity (TRB): 0.001 – 9999 NTU |
Solids (TSS): 0.001 – 500 g/L | |
Repeatability | TSS content: < 4 % |
Turbidity: < 3 % | |
Response Time | 1 s < T90 < 300 s (adjustable) |
Response Time T90 | 1 – 300 s adjustable |
Special Features | Simple Inline installation |
Special notes | Installation note: |
Distance sensor–wall | |
> 10 cm (TSS) | |
Special Notes | Installation note: |
Distance sensor–wall | |
> 50 cm (Turbidity) | |
Warranty | 12 months |
Weight | approx. 2.7 kg |
Weight Sensor | 2.7 |
What’s included? | Turbidity & Suspended Solids sensor, user manual |
Unique Multi-Beam Pulsed Infrared Light System.
Standard Compliant and Precise – Ease of Calibration.
Suitable for Use in Potentially Explosive Atmospheres.
Withstands Difficult Conditions and Harsh Environments.
Decrease polymer cost, digester volume and sludge hauling.