TSS EX1 SC TURBIDITY

TSS EX1 sc Turbidity and Suspended Solids Inline Probe, Stainless Steel

The TSS EX1 sc Inline is a digital process probe for the extremely accurate in pipe measurement of turbidity and suspended solids specially designed for use in potentially explosive atmospheres (Class I Div 2).

Accuracy
Turbidity up to 1000 NTU:
< 5% of the measured value ±0.01 NTU
Ambient Temperature
0 – 50 °C
Application
Hazardous locations
Automatic Wiper
No
Cable Length
10 m (optional extension cables available)
Calibration
Turbidity (TRB): Factory calibrated
Solids (TS): To be calibrated by customer on site
Zero point: Permanently calibrated in the factory
Calibration Method
Turbidity Formazin or StablCal® Standard (at 800 NTU). Requires a calibration kit.
Suspended Solids Sample specific, based on gravimetric analysis with a correction factor procedure.
Controller Compatibility
SC200, SC1000, SC4500. All controllers sold separately
Diameter
48.5 mm
Flow
Max. 3 m/s (the presence of air bubbles affects the measurement)
Includes
Turbidity & Suspended Solids sensor, user manual
Installation style
Ball Valve Insertion
Length
488 mm
Maintenance Interval
1 h/month
Material
Optics Carrier and Sleeve: stainless steel 1.4460 / stainless steel 1.4404
Max Temperature
50
Max. cable length Sensor-to-Controller
100
Measurement Method
Combined multiple beam alternating light method with infrared diode system and beam focusing
Turbidity (TRB): 2-channel 90º scattered light measurement in accordance with DIN EN ISO 7027, wavelength = 860 nm
Solids (TS): 90º and 120º scattered light measurement, wavelength = 860 nm
Measuring Principle
Turbidity: 2-channel 90° scattered light measurement in accordance with DIN/EN 27027/ISO7027
TSS: Modified absorption measurement
Eight-channel multiple-angle measurement, wavelength = 860 nm
Model
TSS EX1 sc
Mounting Configurations
Insertion
Operating Temperature Range
-10 – 50 °C
Parameter
Turbidity, Suspended Solids
Pressure Range
10 bar or 100 m
Range
Turbidity (TRB): 0.001 – 9999 NTU
Solids (TSS): 0.001 – 500 g/L
Repeatability
TSS content: < 4 %
Turbidity: < 3 %
Response Time
1 s < T90 < 300 s (adjustable)
Response Time T90
1 – 300 s adjustable
Special Features
Simple Inline installation
Special notes
Installation note:
Distance sensor–wall
> 10 cm (TSS)
Special Notes
Installation note:
Distance sensor–wall
> 50 cm (Turbidity)
Warranty
12 months
Weight
approx. 2.7 kg
Weight Sensor
2.7
What’s included?
Turbidity & Suspended Solids sensor, user manual

  • Unique Multi-Beam Pulsed Infrared Light System.

  • Standard Compliant and Precise – Ease of Calibration.

  • Suitable for Use in Potentially Explosive Atmospheres.

  • Withstands Difficult Conditions and Harsh Environments.

  • Decrease polymer cost, digester volume and sludge hauling.